Electrical data | |
Power supply type : | Direct current |
Working voltage [V]: | 10 ÷ 30 |
Current consumption [mA]: | < 15 mA @ 24Vdc |
Protection class : | III |
Reverse polarity protection : | Presente |
Outputs | |
Electrical design : | NPN |
Function : | NC |
Max voltage drop [V]: | < 1.8 |
Max output current [mA]: | 200 |
Max switching frequency [Hz]: | 400 |
Short circuit protection : | Present |
Overload protection : | Present |
Detection zone | |
Switching distance-Sn [mm]: | 8 |
Real sensing distance-Sr [mm]: | 8 ±10% |
Operative distance-So [mm]: | 0 ÷ 6.48 |
Extended sensing distance : | Si |
Accuracy and Deviations | |
Correction factor : | Stainless steel: 0.9 – Brass: 0.5 – Aluminium: 0.4 – Copper: 0.4 |
Hysteresis [%Sr]: | < 10 |
Switching point drift [%Sr]: | -10 ÷ +10 |
Repeatability [%Sn]: | < 3 |
Environmental conditions | |
Temperature limits [°C]: | -25 ÷ +70 |
IP rating : | IP65-IP66-IP67 |
Display and control elements | |
Display : | Output switching status – 1 x LED: Yellow |
Mechanical data | |
Housing : | Threded type |
Thread designation : | M18x1 |
Dimensions [mm]: | M18x1 – L=45 |
Materials : | Housing: AISI 303 – Sensing area: POM grey – Lock nuts: Nickel-plated brass |
Mounting : | Embeddable |
Weigth [g]: | 115 |
Electrical connection | |
Cable : | 2 m – PVC/PVC – 3 x 0.35 mm² |
Compliance to Standards / Directives | |
Directives compliance : | 2014/30/EU -Electromagnetic compatibility directive (EMC) |
Standards compliance : | EN60947-5-2 – Product standard |